R.C.C. FOOTINGS

There are mainly two types of R.C.C. footings:

1. One way reinforced footings.
2. Two way reinforced footings.

1. One Way Reinforced Footing: These footings are for the walls. In these footings main reinforcements are in the transverse direction of wall. In longitudinal directions there will be only nominal reinforcement.

2. Two Way Reinforced Footings: For columns two way reinforced footings are provided.
The following types of the footings are common:

(i) Isolated Column Footings: If separate footings are provided for each column, it is called isolated column footing. Figure 1 shows a typical isolated column footing. The size of footing is based on the area required to distribute the load of the columns safely over the soil . These footings are provided over a 100 to 150 mm bed concrete. Required reinforcements and thickness of footing are found by the design engineers. Thickness may be uniform or varying.


(ii) Combined Footings: Common footings may be provided for two columns. This type of footing is necessary when a column is very close to the boundary of the property and hence there is no scope to project footing much beyond the column face. Figure 2 shows a typical combined footing. The footing is to be designed for transferring loads from both columns safely to the soil. The two columns may or may not be connected by a strap beam.


(iii) Continuous Footings: If a footing is common to more than two columns in a row, it is called continuous footing. This type of footing is necessary, if the columns in a row are closer or if SBC of soil is low. Figure 3 shows this type of footing.


(iv) Mat Footing/Raft Footing: If the load on the column is quite high (Multistorey columns) or when the SBC of soil is low, the sizes of isolated columns may work out to be to such an extent that they overlap each other. In such situation a common footing may be provided to several columns as shown in Fig. 4 Such footings are known as raft footings. If the beams are provided in both directions over the footing slab for connecting columns, the raft foundations may be called as grid foundation also. The added advantage of such footing is, settlement is uniform and hence unnecessary stresses are not produced.

Wednesday, November 27, 2019

CONVENTIONAL SPREAD FOOTINGS

This type of foundations are commonly used for walls and masonry columns. These foundations are built after opening the trenches to required depth. Such footings are economical up to a maximum depth of 3 m. As these foundations are suitable depth, they are grouped under shallow foundations.

Figure 1 shows a conventional spread footing for a wall and Fig. 2 shows it for a masonry column.

CONVENTIONAL SPREAD FOOTINGS

Before building these footing trenches are opened to required depth and the soil is rammed well. Then a plain concrete of mix 1 : 4 : 8 is provided. Its thickness varies from 150 to 200 mm. Over this bed, stone masonry footing is built. It is built in courses each course projecting 50 to 75 mm from the top course and height of each course being 150 to 200 mm. In case of wall footing the projections are only one direction while in case of columns, they are in both directions. The projection of bed concrete from the lowest course of foundation masonry is usually 150 mm.

Friday, September 6, 2019

Dimensions of Foundation

Guidelines for minimum dimensions are given below:

(a) Depth of Foundation: For all types of foundations minimum depth required is calculated
using Rankine’s Formula:




However in any case it is not less than 0.9 m. Finding safe bearing of the soil is an expert’s job,
and it is found after conducting tests in field or in Laboratories. However general values for common
soils are listed in Table 1.



(b) Width of Foundation: Width of wall foundations or size of column footing is determined by
first calculating the expected load and then dividing that with SBC. Thus,