Monday, March 2, 2015

Seismic Design, Eccentricity

Offset between center of mass and center of resistance causes eccentricity which causes torsion under seismic load.  The plans at left identify concentric and eccentric conditions:

1  X-direction concentric
    Y-direction eccentric

2  X-direction eccentric
    Y-direction eccentric

3  X-direction concentric
    Y-direction concentric

4  X-direction concentric
    Y-direction concentric

5  X-direction concentric
    Y-direction concentric

X-direction concentric
    Y-direction concentric

Note: Plan 5 provides greater resistance against torsion than plan 6 due to wider wall spacing Plan 6 provides greater bending resistance because walls act together as core and thus provide a greater moment of inertia.